Showing posts with label RTD. Show all posts
Showing posts with label RTD. Show all posts

Tuesday, December 4, 2018

3 Bottom Line Criteria to Help You Choose Between Thermocouples and RTDs

Temperature Sensor Selection Criteria
Both RTD and thermocouple probes monitor temperature but which one is right for your application?

The first question to ask yourself is what is the temperature range you are trying to monitor?
Generally, if the temperature is above a hundred and fifty degrees Celsius, a thermocouple would be used. For anything below a hundred and fifty degrees Celsius, an RTD would be used.

The next question to ask is what is the required sensor accuracy? 
RTDs provide more accurate readings with repeatable results, this is why RTDs are typically used when temperatures are within its monitoring range.

The last question is what is the purchase budget and how many do you need?
Thermocouples can be up to three times less expensive than RTD probes making thermocouples a good choice when purchasing a large quantity or when the budget is tight

These three criteria are VERY basic, and intended just to point you in the right direction. There are many other differences between thermocouples and RTDs that need to be understood before application.  Always consult a temperature sensor application expert prior to installing or specifying a thermocouple or RTD where failure can cause harm.

Duro-Sense Corporation
https://duro-sense.com
(310) 533-6877

Friday, November 9, 2018

Platinum Resistance Temperature Detectors

Platinum Resistance Thermometers Detectors (RTDs) rely on the fact that platinum, like many other metals, exhibits increased electrical resistance as temperature rises. For example, a conventional RTD designed to provide 100 Ohms at 0 °C has a resistance in the neighborhood of 80 Ohms at -50 °C and 120 Ohms at 50 °C, or a sensitivity of about 0.4 Ohms per degree. RTDs constructed to particularly exacting specifications, termed Standard Platinum Resistance Thermometers, are named as the defining measurement tools for interpolating temperatures under ITS-90. In general, RTDs can have high accuracy (0.01 °C), stability, and repeatability across a wide range of temperatures from -200 °C to 500 °C.

Typically the platinum element is formed into thick or thin films, or the platinum wire is arranged in two, three or four helical coils (see diagram, right) – the more coils, the higher the sensitivity. The film or wire is placed inside a glass or ceramic enclosure, and can be supported by loose or compacted MgO. Platinum-based leads connect the probe unit to the thermometer electronics, which convert the electrical signal to temperature.

RTDs are broadly divided into two groups: Industrial RTDs and Standard Platinum Resistance Thermometers, depending on sensitivity and robustness. ASTM and IEC define several classes of RTDs, each with a different set of specifications. An ASTM "Class A" unit, for example, has an out-of-the-box tolerance — maximum permissible error — that ranges from 0.47 °C at -200 °C to 0.13 °C at 0 °C to 0.98 °C at 500 °C.

Advantages

  • Wide temperature range
  • Resistance-temperature relationship is well characterized.
  • Rugged construction in industrial RTDs
  • Available in different shapes and sizes – application specific
  • Can be used with a digital temperature read-out device.

Disadvantages

  • Mechanical shock and vibration will cause drift.
  • Deterioration at elevated temperatures (e.g., >500 °C)
  • 2-and 3-wire devices need lead-wire compensation.
  • Non-hermetically sealed RTDs will deteriorate in environments with excessive moisture.



Post abstracted from "Mercury Thermometer Alternatives: Platinum Resistance Thermometers (PRTs)" by NIST.

Friday, September 28, 2018

Advantage and Disadvantages of Common Temperature Sensors

THERMOCOUPLE

thermocouple
Thermocouple
Due to their simplicity, reliability, and relatively low cost, thermocouples are widely used. They are self-powered, eliminating the need for a separate power supply to the sensor. Thermocouples are fairly durable when they are appropriately chosen for a given application. Thermocouples also can be used in high-temperature applications.

Thermocouple Advantages:
  • Self-powered
  • Simple
  • Rugged
  • Inexpensive
  • Many applications
  • Wide temperature range
  • Fast response
Thermocouple Disadvantages:
  • Nonlinear output signal
  • Low voltage
  • Reference required
  • Accuracy is function of two separate measurements
  • Least sensitive
  • Sensor cannot be recalibrated
  • Least stable

RTD

RTD
RTD
Resistance temperature detectors are attractive alternatives to thermocouples when high accuracy, stability, and linearity (i.e., how closely the calibration curve resembles a straight line) of output are desired. The superior linearity of relative resistance response to temperature allows simpler signal processing devices to be used with RTD’s than with thermocouples. Resistance Temperature Detector’s can withstand temperatures up to approximately 800 C (~1500 F).

RTD Advantages:
  • More stable at moderate temperatures
  • High levels of accuracy
  • Relatively linear output signal
RTD Disadvantages:
  • Expensive
  • Self-heating
  • Lower temperature range

THERMISTOR

Thermistor
Thermistor
Thermistors work similarly to RTD’s in that they are a resistance measuring device, but instead of using pure metal, thermistors use a very inexpensive polymer or ceramic material as the element.

Thermistor Advantages:
  • High output
  • Fast
  • Two-wire ohms measurement
Thermistor Disadvantages:
  • Nonlinear
  • Limited temperature range
  • Fragile
  • Current source required
  • Self-heating

Sunday, September 23, 2018

Monday, September 10, 2018

Thermowells

Thermowell
Thermowell (Duro-Sense)
One of the most important accessories for any temperature-sensing element is a pressure-tight sheath known as a thermowell. This may be thought of as a thermally conductive protrusion into a process vessel or pipe allowing a temperature-sensitive instrument to detect process temperature without opening a hole in the vessel or pipe. Thermowells are critically important for installations where the temperature element (RTD, thermocouple, etc.) must be replaceable without de-pressurizing the process.

Thermowells may be made out of any material that is thermally conductive, pressure-tight, and not chemically reactive with the process. Most thermowells are formed out of either metal (stainless steel or other alloy) or ceramic materials. A simple diagram showing a thermowell in use with a temperature sensor (RTD) is shown here:
Thermowell

As useful as thermowells are, they are not without their caveats. All thermowells, no matter how well they may be installed, increase the first-order time lag of the temperature sensor by virtue of their mass and specific heat value. It should be intuitively obvious that a few pounds of metal will not heat up and cool down as fast as a few ounces’ worth of RTD or thermocouple, and therefore the addition of a thermowell to the sensing element will decrease the responsiveness of any temperature- sensing element. What is not so obvious is that such time lags, if severe enough, may compromise the stability of feedback control. A control system receiving a “delayed” temperature measurement will not see the live temperature of the process in real time due to this lag.

Thermowell
RTD with Thermowell 
A potential problem with thermowells is incorrect installation of the temperature-sensing element. The element must be inserted with full contact at the bottom of the thermowell’s blind hole. If any air gap is allowed to exist between the end of the temperature element and the bottom of the thermowell’s hole, this will add a second time lag to the measurement system26. Some thermowells include a spring clip in the bottom of the blind hole to help maintain constant metal-to-metal contact between the sensing element and the thermowell wall.

Reprinted from Lessons In Industrial Instrumentation by Tony R. Kuphaldt – under the terms and conditions of the Creative Commons Attribution 4.0 International Public License.

Tuesday, August 28, 2018

Temperature Transmitters

Temperature Transmitters
Temperature Transmitters (Duro-Sense)
A temperature transmitter is generally described as a device, which on the input side is connected to some sort of temperature sensor and on the output side generates a signal that is amplified and modified in different ways. Normally the output signal is directly proportional to the measured temperature within a defined measurement range. Many additional features can be added depending on the type of transmitter being used. The features of the temperature transmitter are often described by using different terms with respect to technology, mounting method, functions, etc. The following list is a brief summary of these terms.

Analog Transmitters: These transmitters are designed on analog circuit technology. They normally offer basic functions such as temperature linearization and sensor break technology. Sometimes they are adjustable for different measuring ranges, often with a fast response time.

Digital Transmitters: This transmitter type is mainly based on a microprocessor. They are often called intelligent transmitters, because they normally offer many extra features, which are not possible to realize in analog transmitters.

In-Head Transmitters: These transmitters are designed for mounting in the connection heads of temperature sensors. All Duro-Sense in-head transmitters fit into DIN B heads or larger. Special care has to be devoted to the ruggedness because of the harsh conditions that sometimes exist.

DIN Rail Transmitters: DIN rail transmitters are designed to be snapped onto a DIN rail. Duro-Sense DIN rail transmitters fit on a 35mm rail according to DIN EN 50022.

RTD Transmitters: RTD transmitters are used only for RTD sensors. (Pt100, Pt1000, Ni100, etc.). Normally they can handle only one RTD type. Most Duro-Sense transmitters can handle more than one type of RTD and are either fix- ranged or adjustable. They all have linear output.

Thermocouple TransmitterThermocouple Transmitters: Thermocouple transmitters measure a MV signal form the thermocouple and compensates for the temperature of the cold junction. The cold junction compensation is normally made by measuring the terminal temperature. Alternatively, some transmitters can be adjusted to compensate for an external fixed cold junction temperature. Pure thermocouple transmitters are often not temperature linearized due to the complicated unlinearity of the thermocouples.

Analog Output: The output signal is a current (4-20mA). Some transmitters are available with 0-20mA or 0-10mA output. The signal is normally proportional to the measured value within a defined measurement range.

Digital Output: The measured value (temperature) is presented as a binary coded message. So called Fieldbus transmitters use this technique. The Fieldbus transmitters on the market today use different standards for the communication thus creating some problems when integrating them with other instrumentation. Examples of standard available are: PROFIBUS, Interbus, Foundation Fieldbus, LonWorks and CAN-bus.

Analog and Digital Output: The HART transmitters have an analog output with a superimposed digital signal on the same wires. Typically, the analog signal is used for normal measurements and the digital signal only for temporary measurements, because of the low communication speed. The digital signal is mainly used for configuration and status information.

Isolated Transmitters: Isolated transmitters have no leading connections between circuits that are isolated from each other. The isolation effectively eliminates the risk for circulating currents and facilitates the connection of transmitters to control systems with grounded inputs.

Non-Isolated Transmitters: These transmitters have leading connections between, for instance, input and output circuits. They should be used with care.

For more information on temperature transmitters, visit https://duro-sense.com or call 310-533-6877.

Friday, August 17, 2018

Temperature Sensors for the Toughest Applications

Duro-Sense Corporation
Click for larger view.
Duro-Sense Corporation manufactures the finest quality temperature sensors available. The company has a long history of supplying thermocouples and RTDs to the top manufacturers in aerospace, medical equipment, semiconductor processing, plastics processing, and heavy industry.  From large industrial thermocouples used in primary metal production, to miniature, discreet sensors used in military aircraft, Duro-Sense products are proven to be ultra-reliable, accurate, and of extremely high value.

All Duro-Sense customers benefit from years of tackling difficult applications. By implementing stringent quality practices and advanced manufacturing processes, Duro-Sense continues to solve the most challenging temperature sensing applications.

Duro-Sense is a one-stop, full service provider of anything related to temperature sensing. Service. Quality. On-time delivery.

Rely on the Duro-Sense difference.
www.duro-sense.com  |  310-533-6877.



Friday, August 3, 2018

Video: Comparison of Thermocouples and RTDs

The video below describes the basic differences between industrial thermocouples and RTDs.


Duro-Sense Corporation provides the thermocouples, RTDs, thermowells, and accessories to the aerospace, aviation, process control, medical, R&D, power generation, alternative energy, plastics, primary metals, high-tech and OEM industries.

https://duro-sense.com
310-533-6877

Friday, July 6, 2018

Common Terminology Used in Temperature Measurement and Process Control

Terminology Used in Temperature Measurement
Accuracy: The closeness of an indicator or reading of a measurement device to the actual value of the quantity being measured; usually expressed as ± percent of the full scale output or reading.

Drift: The change in output or set point value over long periods of time due to such factors as temperature, voltage, and time.

Hysteresis: The difference in output after a full cycle in which the input value approaches the reference point (conditions) with increasing, then decreasing values or vice versa; it is measured by decreasing the input to one extreme (minimum or maximum value), then to the other extreme, then returning the input to the reference (starting) value.

Linearity: How closely the output of a sensor approximates a straight line when the applied input is linear.

Noise: An unwanted electrical interference on signal wires.

Nonlinearity: The difference between the actual deflection curve of a unit and a straight line drawn between the upper and lower range terminal values of the deflection, expressed as a percentage of full range deflection.

Precision: The degree of agreement between a number of independent observations of the same physical quantity obtained under the same conditions.

Repeatability: The ability of a sensor to reproduce output readings when the same input value is applied to it consecutively under the same conditions.

Resolution: The smallest detectable increment of measurement.

RTD: Abbreviation for "resistance temperature detector". Resistance temperature detectors are temperature sensors that are widely used because of their high accuracy, stability, and linearity. They work on the principle that the resistivity of metals is dependent upon temperature; as temperature increases, resistance increases. Resistance Temperature Detector’s can withstand temperatures up to approximately 800 C (~1500 F).

Sensitivity: The minimum change in input signal to which an instrument can respond. Stability: The ability of an instrument to provide consistent output over an extended
period during which a constant input is applied.

Thermocouple: A temperature sensing device widely used because they are relatively low cost, self-powered, durable and capable sensing high temperatures. Thermocouples generate and micro voltage in relation to temperature change.

Zero balance: The ability of the transducer to output a value of zero at the electronic null
point.

Friday, June 8, 2018

Precision RTD's (Resistance Temperature Detectors)

Duro-Sense RTDs, thermowells, and accessories provide high quality solutions to the aerospace, aviation, process control, medical, R&D, power generation, alternative energy, plastics, primary metals, high-tech and OEM industries.

https://duro-sense.com
310-533-6877

Friday, May 25, 2018

Power Plant Temperature Sensors

Power plants (generating facilities) transform the mechanical energy of a spinning generator into electrical energy. Heat (from flame, nuclear reaction, or chemical reaction) is used to create steam that, in turn, produces the mechanical energy to drive turbines. There are many areas where precision temperature measurement and monitoring is critical to keep power plant systems running. Thermocouples and RTD sensors provide accurate, repeatable, and reliable  measurement.

Duro-Sense
https://duro-sense.com
Phone: 310-533-6877


Wednesday, May 16, 2018

RTD and Thermocouple Selection and Location for Optimal Control

Loop diagram
Loop diagram *
A perfectly designed temperature loop would precisely balance the power required to heat the media to it's desired temperature while compensating for system losses. In the real world however, there are many external variables that upset the balance between energy input and desired temperature. To offset these external variables and ensure adequate power is available to do the work, energy calculations with liberal safety factors are coupled with temperature controllers that throttle or proportion the amount of energy added to the process.

Most temperature control loops have (5) four major components:

1) The media to be heated (e.g. metal platen, a tank of liquid, a stream of gas)
2) A energy source (e.g. electric heater, steam, hot oil, flame)
3) A temperature sensor (thermocouple, RTD)
4) A controller (e.g. electronic thermostat, PID controller)
5) Control element (e.g. control valve, SCR, SSR)

Temperature controllers provide sophisticated functions that "learn" or understand the relationship between available power and sensor temperature. They then adjust the amount of energy (heat) added, based on the current reading of the sensor and the desired temperature setpoint.  Unfortunately, temperature controllers are often relied upon to overcome the oversights and inadequacies of poor control loop design.

Lag time
Lag time *
In poor control situations the controller usually takes the blame, when in actuality,  the problem lies in the system design. The controller's actions are a function of the difference between setpoint and sensor reading, the availability of energy to eliminate that error, and the sensor lag time. The further the sensor or energy source is located from the process media, the wider the swings in energy input will be, and therefore produce a more difficult loop to balance. Considering this, it is important to optimize the sensor (thermocouple or RTD) placement. Any distance or barrier between sensor and process media introduces lag which is an impediment to close control.

In the most ideal situation, temperature sensors, the energy source and process media would all be at the same physical location. Since it's virtually impossible to accomplish this, compromises have to be made to allow for the mechanical, physical, and electrical realities of the application. Here are some practical recommendations for sensor selection and placement to improve temperature loop performance:
  • Thermocouples, because of their low mass generally have a response advantage over RTDs.
  • Exposed junction thermocouples are the fastest responding (least lag) sensor choice, but they are also the most prone to physical and chemical damage.
  • Narrow, sheathed, grounded junction magnesium oxide insulated thermocouples are nearly as fast as exposed junctions, and provide protection from the process media.
  • Applications that require protection sheaths and thermowells for RTDs and thermocouples increase sensor lag time.
  • An immersion length of at least 10 times the diameter of the thermowell or sensor sheath should be used to minimize heat loss along the sensor sheath or thermowell wall from tip to process connection.
  • Where possible, insert the temperature sensor in a pipe elbow into the oncoming flow.
  • Tapered, swaged, or stepped thermowells are  faster responding
  • Always make sure the fit between sensor outer diameter and thermowell inner diameter is tight, and that the tip of the sensor is in direct contact with the thermowell. 

* Images courtesy of Tony Kuphaldt and his book "Lessons In Industrial Instrumentation"

Saturday, April 14, 2018

Thermocouples and RTDs Used in Power Plants

Thermocouple and RTD Used in Power Plants
The majority of temperature measuring in a electrical generating plant are done with RTDs (resistance temperature detectors) and thermocouples (T/Cs).

RTD's are devices that produce a measurable resistance change with temperature change, while thermocouples produce a mV signal change in response to temperature change.

RTD's are constructed of a a thin conductor (nickel, platinum, copper) wrapped around a glass or ceramic bobbin, inserted into a protective sheath, and backfilled with an electrically inert, but thermally conductive, material.

Power plants historically use 100-ohm platinum, 100-ohm nickel, 120-ohm nickel, and 10-ohm copper RTDs. While providing excellent accuracy and long term stability, RTDs are prone to mechanical shock and vibration found in a generating facility. They are more expensive than thermocouples and application temperatures are generally limited to around up to 1110°F. One very attractive feature for RTDs are their inherent electrical noise immunity, a significant advantage over thermocouples. Finally, common, inexpensive instrument wire is used for connecting the RTD to the measuring instrumentation.

A thermocouple consists of two wires, made of dissimilar alloys, joined together at each end. One junction is designated the hot junction, the other junction is designated as the cold (or reference junction). When the hot junction experiences a change in temperature, a voltage is generated that is proportional to the difference in temperature between the hot and cold junctions. 

T/Cs are be made of different combinations of alloys and "calibrations" for use at various temperature ranges. The most common thermocouples for the power generation industry applications under 1800 °F are type are J, K and N ; for applications over 1800 °F,  types R and S are common. Aside from the obvious higher temperature capability, thermocouples provide faster response and greater shock and vibration endurance. However, thermocouples, due to the minuter signals the produce, are more susceptible to conducted and radiated electrical noise.  Another concern with thermocouples are their degradation over time when used at elevated temperatures and are therefore less stable than RTDs. One final issue is the need to run costly thermocouple extension wire of the same type as the thermocouple between sensor and measuring instrument.

When in doubt about which sensor is best to apply in a power plant application, contact an application expert who will help you choose the ideal sensor for your requirements.

https://duro-sense.com
Ph: 310-533-6877




Monday, March 26, 2018

The 3 Most Common Temperature Sensors: Thermocouples, RTD's and Thermistors

This post explains the basic operation of the three most common temperature sensing elements - thermocouples, RTD's and thermistors.

Thermocouple
Thermocouple (image courtesy of Duro-Sense)
A thermocouple is a temperature sensor that produces a micro-voltage from a phenomena called the Seebeck Effect. In simple terms, when the junction of two different (dissimilar) metals varies in temperature from a second junction (called the reference junction), a voltage is produced. When the reference junction temperature is known and maintained, the voltage produced by the sensing junction can be measured and directly applied to the change in the sensing junctions' temperature.

Thermocouples are widely used for industrial and commercial temperate control because they are inexpensive, fairly accurate, have a fairly linear temperature-to-signal output curve, come in many “types” (different metal alloys) for many different temperature ranges, and are easily interchangeable. They require no external power to work and can be used in continuous temperature measurement applications from -185 Deg. Celsius (Type T) up to 1700 Deg. Celsius (Type B).

Common application for thermocouples are industrial processes, the plastics industry, kilns, boilers, steel making, power generation, gas turbine exhaust and diesel engines, They also have many consumer uses such as temperature sensors in thermostats and flame sensors, and for consumer cooking and heating equipment.

resistance temperature detectors
Wire-wound RTD (image courtesy of Wikipedia)
RTD’s (resistance temperature detectors), are temperature sensors that measure a change in resistance as the temperature of the RTD changes. They are normally designed as a fine wire coiled around a bobbin (made of glass or ceramic), and inserted into a protective sheath. The can also be manufactured as a thin-film element with the pure metal deposited on a ceramic base much like a circuit on a circuit board.

The RTD wire is usually a pure metal such as platinum, nickel or copper because these metals have a predictable change in resistance as the temperature changes. RTD’s offer considerably higher accuracy and repeatability than thermocouples and can be used up to 600 Deg. Celsius. They are most often used in biomedical applications, semiconductor processing and industrial applications where accuracy is important. Because they are made of pure metals, they tend to more costly than thermocouples. RTD’s do need to be supplied an excitation voltage from the control circuitry as well.

Thermistor
Thermistor (image courtesy of Wikipedia)
The third most common temperature sensor is the thermistor. Thermistors work similarly to RTD’s in that they are a resistance measuring device, but instead of using pure metal, thermistors use a very inexpensive polymer or ceramic material as the element. The practical application difference between thermistors and RTD’s is the resistance curve of thermistors is very non-linear, making them useful only over a narrow temperature range.

Thermistors however are very inexpensive and have a very fast response. They also come in two varieties, positive temperature coefficient (PTC - resistance increases with increasing temperature), and negative temperature coefficient (NTC - resistance decreases with increasing temperature). Thermistors are used widely in monitoring temperature of circuit boards, digital thermostats, food processing, and consumer appliances.

For more information, contact Duro-Sense by calling 310-533-6877 or visit https://duro-sense.com.

Monday, February 5, 2018

Temperature Sensor Basics: RTDs (Resistance Temperature Detectors)

RTD
RTD temperature sensor with
threaded connector (Duro-Sense)
Resistance Temperature Detectors (RTD’s) operate under the principle that the electrical resistance of certain metals increases or decreases in a repeatable and predictable manner with a temperature change. RTD’s may have a lower temperature range than some thermocouples and a slower response time, however, they are more stable and repeatable over long periods of time. RTD’s offer considerably higher accuracy and repeatability than thermocouples and can be used up to 600 Deg. Celsius. 

RTD diagram
Simple RTD diagram (courtesy of Wikipedia)
The RTD wire is usually a pure metal such as platinum, nickel or copper because these metals have a predictable change in resistance as the temperature changes. They are normally designed as a fine wire coiled around a bobbin (made of glass or ceramic), and inserted into a protective sheath. Because they are made of pure metals, they tend to more costly than thermocouples. RTD’s do need to be supplied an excitation voltage from the control circuitry as well. RTD’s higher signal output makes them easier to interface with computers and data loggers and reduces the effects of radio frequency interference.

RTD’s are used in many industries including the plastic processing industry, environmental test chambers, motor windings, pumps and bearings, ovens, kilns, waste treatment and the pulp and paper industry.  Because of their accuracy and repeatability, they are also commonly used in biomedical applications, aerospace, and semiconductor processing.

https://duro-sense.com
310-533-6877

Wednesday, January 10, 2018

Get to Know Duro-Sense

Here's a short video to learn more about Duro-Sense Corporation. Hope you enjoy.

Tuesday, January 9, 2018

Welcome to the Duro-Sense Blog

Welcome! We hope (over time) you find this blog interesting to visit and it becomes a trusted resource for all-things-temperature-measurement.

We plan on weekly educational and informative blog posts about innovative temperature sensor solutions, insight to how sensors work, and new products that solve tough engineering challenges.

Specific products we'll be discussing are:
Please come back often!