Thermocouple Extension Wire

Thermocouple Extension Wire
Thermocouple extension wire is a single pair wire that cannot be made into a thermocouple, but is used to carry the signal from a thermocouple to the recorder, controller, or instrument reading the signal.

Extension grade wire is used to carry a signal representing the higher temperature seen by the sensing location, but extension wire itself cannot be generally exposed to those higher temperatures.

Extension wire cannot be used to make a thermocouple, but thermocouple wire can be used as extension wire. Insulation is typically PVC, but other option are available.

ThermocoupleMulti-pair extension wire is simply more than a single pair in the same jacket.  It is extension onlyand is usually available in 2, 4, 6, 8, 12, 16, and 24 pairs. It is used primarily when a contractor has to run multiple runs of wire. It allows them to run one piece of wire rather than multiple individual runs.

For more information on all varieties of thermocouple wire, contact Duro-Sense by calling 310-533-6877 or visiting https://duro-sense.com.

Friday, May 24, 2019

Quick Comparison of Temperature Sensors


Thermocouples are commonly used because of their simplicity, reliability, and relative low cost. They are self-powered and eliminate the need for a separate sensor power supply. Thermocouples are quite durable when selected for a given application appropriately. Thermocouples can also be used for applications with high temperatures.

Resistance temperature detectors (RTDs) are attractive alternatives to thermocouples when the output is desired to be highly accurate, stable and linear (i.e. just how close the calibration curve looks a straight line). The superior linearity of relative temperature resistance enables simpler signal processing devices for RTDs than thermocouples.

Thermistors are similar to RTD because they're a resistance measurement device, but thermistors use a very cheap polymer or ceramic material as the element in lieu of the use of pure metal.

For more information on any type of industrial or OEM temperature sensor, contact Duro-Sense by calling 310-533-6877 or by visiting https://duro-sense.com.

Friday, April 19, 2019

Thermocouples: Proper Use, Recommended Practices, and Avoiding Problems

High temperature thermocouples

Proper use and maintenance of thermocouple systems begin with good system design based on the strengths and weaknesses of various thermocouple types. Because these sensors contain sensitive electronics, general good practice includes use of shielded cases and twisted- pair wire, use of proper sheathing, avoidance of steep temperature gradients, use of large-gauge extension wire, and use of guarded integrating voltmeters or ohmmeters, which electronically filter out unwanted signals. The signal conditioner should be located as close as possible to the sensor, and twisted copper-wire pairs should be used to transmit the signal to the control station. To minimize electromagnetic field interference, sensor system wires should not be located parallel to power supply cables. The primary causes of loss of calibration in thermocouples include the following:
  1. Electric “noise” from nearby motors, electric furnaces, or other such electrically noisy equipment;
  2. Radio frequency interference from the use of hand-held radios near the instrument.
  3. “Ground loops” that result when condensation and corrosion ground the thermocouple and create a ground loop circuit with another ground connection in the sensing circuit.
Most problems with thermocouples are aggravated by use of the thermocouple to measure temperatures that approach or exceed their upper temperature limits. Careful recording of events that could affect measurements should be kept in a logbook. Any adjustments or calibrations should also be recorded. The logbook should contain the names of individuals performing maintenance and calibrations as well as defined procedures. In systems monitoring many locations, such a log is especially useful for fault diagnosis.

Thermocouples sometimes experience catastrophic failures, which may be preceded by extreme oscillations or erratic readings. In such cases, all connections associated with the thermocouple should be checked for loose screws, oxidation, and galvanic corrosion. In many cases, drift may be a more serious problem because it can go unnoticed for long periods of time. The most common causes of loss of calibration are excessive heat, work hardening, and contamination. Work hardening generally is due to excessive bending or vibration and can be prevented with properly designed thermowells, insertion lengths, and materials. Contamination is caused by chemicals and moisture, which sometimes attack wiring by penetrating sheaths, and can result in short-circuiting. A simple test to check for this problem is to disconnect the sensor at its closest connection and check for electrical continuity between the wires and the sheath using a multimeter. If the meter indicates continuity, the sensor should be replaced. Because the electromotive force (EMF) produced by thermocouples is so small, electrical noise can severely affect thermocouple performance. For that reason, it also is very important that transmitters be isolated. Thermocouples used in the vicinity of electrostatic precipitators must be shielded to avoid electrical interference. If the potential electrical interference is high, an RTD or other type of sensor may be preferred to thermocouples. With respect to thermocouple and protection tube selection, the following should be noted:
  1. Type J thermocouples particularly should not be used in applications in which they might be exposed to moisture because the iron in the thermocouple will rust and deteriorate quickly;
  2. Type K thermocouples should not be used in the presence of sulfur, which causes the element to corrode; because cutting oils often contain sulfur, protection tubes should be degreased before being used; stainless steel sheaths should be used to protect Type K thermocouples in stacks where SO2 emissions are significant;
  3. Platinum thermocouple elements (Types R, S, or B) should not be used with metal protection tubes unless the tubes have a ceramic lining because the metal will contaminate the platinum;
  4. Ceramic, silicon carbide, and composite (metal ceramic, Cerite-II, Cerite-III) protection tubes are subject to thermal shock and should be preheated prior to inserting in high temperature process environments; and
  5. Molybdenum - or tantalum-sheathed thermocouples will fail rapidly if placed in oxidizing atmospheres.
During one study of thermocouple performance, 24 combinations of thermocouple and sheath material types were tested at temperatures up to 1200 C (2200 F). The results indicated that above 600 C (1110 F) thermocouples are affected by complex chemical interactions between their components; even though wires and sheaths were physically separated, exchange of constituents occurred. The study concluded that thermocouples maintain calibration better if sheath material is similar in composition to thermocouple alloys. By using similar alloys longer performance can be expected for sensors subjected to temperatures above 600 C (1110 F), and the use of similar alloys is essential for temperatures above 1000 C (1830 F).

For more information on the proper use of thermocouples, contact Duro-Sense Corporation by calling (310) 533-6877 or visit their website at https://duro-sense.com.

Reprinted from CAM Technical Guidance Document courtesy of EPA.gov.

Sunday, March 31, 2019

Digital Food Thermometers: Thermocouples

Digital Food Thermometers
Specialized thermocouple, with handle and sharpened point,
 used in food preparation.
Of all food thermometers, thermocouple thermometers reach and display the final temperature the fastest - within 2 to 5 seconds. The temperature is indicated on a digital display.

A thermocouple measures temperature at the junction of two fine wires located in the tip of the probe. Thermocouples used in scientific laboratories have very thin probes, similar to hypodermic needles, while others may have a thickness of 1/16 of an inch.

Since thermocouple thermometers respond so rapidly, the temperature can be quickly checked in a number of locations to ensure that the food is safely cooked. This is especially useful for cooking large foods, such as roasts or turkeys, when checking the temperature in more than one place is advised. The thin probe of the thermocouple also enables it to accurately read the temperature of thin foods such as hamburger patties, pork chops, and chicken breasts.

Thermocouples are not designed to remain in the food while it's cooking. They should be used near the end of the estimated cooking time to check for final cooking temperatures. To prevent overcooking, check the temperature before the food is expected to finish cooking.

Thermocouples can be calibrated for accuracy.

For more information of food industry thermocouples, contact Duro-Sense Corporation by calling 310-533-6877 or visiting https://duro-sense.com.

Monday, March 25, 2019

A Pro and Con Comparison of Thermocouples and RTDs


Thermocouple Advantages 
  • Inexpensive
  • Wide temperature range
  • Various types, sizes and application methods
  • Remote read back
  • Read back electronics can be simple
  • Usable in virtually any environment
Thermocouple Disadvantages
  • Requires cold junction compensation
  • Slow response time
  • Not as accurate as many other devices without good CJC and calibration
  • Susceptible to noise
  • Connection cable/wire is expensive compared to copper conductors
  • Cable/wire length is limited
RTD Advantages
  • More linear than thermocouples
  • Cold junction not an issue
  • Special cable/wire not needed
  • Cable/wire length can be much longer than TC’s
  • Better noise immunity
  • More stable over time than thermocouples
  • Remote read back
  • Usable in virtually any environment
RTD Disadvantages
  • More expensive than thermocouples
  • More delicate than thermocouples unless encased
  • Not as wide of temperature range as thermocouples
  • Requires more conductors per device
  • Read back electronics more complex