Sunday, March 31, 2019

Digital Food Thermometers: Thermocouples

Digital Food Thermometers
Specialized thermocouple, with handle and sharpened point,
 used in food preparation.
Of all food thermometers, thermocouple thermometers reach and display the final temperature the fastest - within 2 to 5 seconds. The temperature is indicated on a digital display.

A thermocouple measures temperature at the junction of two fine wires located in the tip of the probe. Thermocouples used in scientific laboratories have very thin probes, similar to hypodermic needles, while others may have a thickness of 1/16 of an inch.

Since thermocouple thermometers respond so rapidly, the temperature can be quickly checked in a number of locations to ensure that the food is safely cooked. This is especially useful for cooking large foods, such as roasts or turkeys, when checking the temperature in more than one place is advised. The thin probe of the thermocouple also enables it to accurately read the temperature of thin foods such as hamburger patties, pork chops, and chicken breasts.

Thermocouples are not designed to remain in the food while it's cooking. They should be used near the end of the estimated cooking time to check for final cooking temperatures. To prevent overcooking, check the temperature before the food is expected to finish cooking.

Thermocouples can be calibrated for accuracy.

For more information of food industry thermocouples, contact Duro-Sense Corporation by calling 310-533-6877 or visiting https://duro-sense.com.

Monday, March 25, 2019

A Pro and Con Comparison of Thermocouples and RTDs


Thermocouple Advantages 
  • Inexpensive
  • Wide temperature range
  • Various types, sizes and application methods
  • Remote read back
  • Read back electronics can be simple
  • Usable in virtually any environment
Thermocouple Disadvantages
  • Requires cold junction compensation
  • Slow response time
  • Not as accurate as many other devices without good CJC and calibration
  • Susceptible to noise
  • Connection cable/wire is expensive compared to copper conductors
  • Cable/wire length is limited
RTD Advantages
  • More linear than thermocouples
  • Cold junction not an issue
  • Special cable/wire not needed
  • Cable/wire length can be much longer than TC’s
  • Better noise immunity
  • More stable over time than thermocouples
  • Remote read back
  • Usable in virtually any environment
RTD Disadvantages
  • More expensive than thermocouples
  • More delicate than thermocouples unless encased
  • Not as wide of temperature range as thermocouples
  • Requires more conductors per device
  • Read back electronics more complex

Tuesday, March 12, 2019

Theory of RTD Operation

Theory of RTD OperationAn RTD is a temperature measuring device that changes resistance with temperature change, rather than changing voltage, as with a thermocouple.

Most commonly used is the platinum 100 ohm RTD because of their stability in air and linearity. Their resistance is 100 ohms @ 0 Deg.C and increases with temperature.

Theory of RTD OperationCommon terms associated with RTD’s are temperature coefficient or alpha, and tolerance class.

Alpha is ohms per ohm per Deg.C.
The average resistance change per unit of temperature from boiling point to ice point of water:

  • Rboiling – Rice point/100deg/100ohms
  • 138.5 – 100.0/100/100 = .00385


Tolerance class is the amount an RTD will differ from the standard resistance curve per Deg.C.

  • Class A (+/- .15 + .002*t)
  • @ temp of 100DegC = +/- .35DegC

When ordering an RTD, a tolerance class will be part of the order, dependent on the application. IEC 751 stipulates that the RTD be marked with their nominal R0 value, their tolerance class, the wiring configuration and the temperature range.
Theory of RTD Operation
3-wire configuration

  • Pt100 / A / 3 / -100/+200  = Platinum 100 Ohm / Class A / 3-Wire / -100 to +200 Deg.C
The most common RTD configuration is the 3-wire type. This configuration is more than adequate for 99.9% of applications. If absolute accuracy is needed, a fourth wire can be introduced, but rarely is it worth the added cost.
Theory of RTD Operation
2-wire configuration

Another configuration is a two wire RTD with a stand-alone loop. (Probably rarely used today).

Since the RTD is a resistance device, the resistance of the wires used to connect the RTD to the measurement meter introduces errors and must be known. This is the reason a third (or fourth), wire is used.

Theory of RTD Operation
3rd wire used to cancel wire error
First the meter reads the resistance of the two common wires to determine the value of Rwire. For a three wire RTD, it is assumed that this resistance is the same as that of one common and one non-common wire.

Then the meter reads the resistance of one of the common wires, the RTD, and the non-common wire to determine Rtotal

Theory of RTD Operation
Meter reading 2 common wires
Meter electronics and software then subtract Rwire from Rtotal to get Rt which is then converted to a temperature.


Theory of RTD Operation





Rt = Rtotal – Rwire



Thursday, February 28, 2019

Theory of Thermocouple Operation

  • A thermocouple is a simple temperature measurement device consisting of a junction of two dissimilar metals.
  • Contrary to popular belief, the voltage measured (and converted to a temperature) is not a function of the junction alone. Rather it is the temperature difference (or gradient) between the junction (or hot), end and the reference (or cold), end.
  • A thermocouple circuit whose junction and reference are the same temperature will measure no temperature (0V).
  • If this were not true, we could create a self-sustaining voltage generator using a thermocouple, a resistive load and an oven, that would require energy only at start-up.
Theory of Thermocouple Operation

The temperature equation for the simplest of thermocouple circuits shown above is:

T = Tjunc – Tref

Where T is the desired measurement, Tjunc is the hot junction temperature and Tref is the reference
temperature, or cold end.

For simplicity’s sake, we use T, Tjunc and Tref here, but in reality these are voltages that are later converted to a temperature.

Cold Junctions
Theory of Thermocouple Operation

The temperature equation for this diagram is:
T = Tjunc – Tcj1 – Tcj2

A fundamental problem when using thermocouples is the fact the when connected to a measurement device (voltmeter or TC meter), a third metal is introduced (the connecting terminals), and two more thermocouple junctions are created. These adversely affect the temperature being measured. The new, (and unwanted), junctions are referred to as “cold junctions” and need some type of “cold junction compensation” in order to make accurate measurements.

In addition to the added variables in the previous equation, the temperature of the cold junctions
(reference end), is still not known. The following rule helps things out a bit:
  • If both TC connections to the meter are of the same metal or alloy, they cancel each other and have no affect on the measurement, as long both connections are at the same temperature (which can be assumed).
Since the definition of a thermocouple states that it must be of dissimilar metals, a second thermocouple must be introduced to the circuit to achieve this. This was the first of what is commonly called “cold junction compensation”

By adding a second series thermocouple suspended in an ice bath, the cold junctions at the meter are of identical metals and cancel each other. In addition, the temperature of the ice bath is known to be 0 Deg. C and becomes the reference end of the thermocouple.

The temperature equation is now simplified and once again becomes:

T = Tjunc – Tref
Theory of Thermocouple Operation
While the ice bath reference junction eliminates errors, it is clearly impractical for most, if not all applications.  Fortunately, all of today’s thermocouple read back options (meters, chart recorders, PLCs, etc.), come equipped with cold junction compensation, usually a thermistor and associated circuitry and software. By taking the cold junction worries out of the picture, the thermocouple remains one of the simplest, most robust and widely used temperature measurement devices around.

Monday, February 25, 2019

Thermocouple Wire Insulation Materials

Thermocouple Wire Insulation

Insulated thermocouple wire is single pair wire that can be made into a thermocouple. Thermocouple wire is available with many types of electrical insulation. The choice of the proper insulation material is based on cost, temperature rating, chemical & UV resistance and wear resistance. Below is a run-down of the most common thermocouple wire insulation materials.

Nylon
  • Suggested operating range: -85°F to 250°F (-65°C to 121°C)
  • Nylon provides high tensile, impact and flexural resistance.  It has excellent resistance to abrasion and is unaffected by most alkalis, oil, grease, dilute mineral acids and most organic acids.  It is inert to most organic solvents including hydraulic fluid and aviation oil. The individual conductors and outer jacket are extruded.
Fluorinated Ethylene Propylene (FEP) 
  • Suggested operating range: -90°F to 400°F (-67°C to 204°C)
  • FEP retains useful strength and flexibility over broad ranges of environmental temperature or thermal aging. FEP is flame retardant and non-propagating in fire conditions. It is moisture and chemical resistant and accepted for use around food and pharmaceuticals. The individual conductors and outer jacket are extruded.
Perfluoroalkoxy (PFA) 
  • Suggested operating range: -328°F to 500°F (-200°C to 260°C)
  • Flame retardant PFA provides flexibility and toughness with stress crack resistance, resistance to weather, non-aging characteristics and a low coefficient of friction.  PFA also provides outstanding electrical characteristics, as well as resistance to virtually all chemicals.  The individual conductors and outer jacket are extruded.
Tetrafluoroethylene (TFE) 
  • Suggested operating range: -328°F to 500°F (-200°C to 260°C)
  • TFE is flame retardant (passes IEEE 383 & VW-1 flame tests) and has excellent solvent and abrasion resistance.  TFE is unaffected by long term exposure to virtually all chemicals and solder iron temperatures. The individual conductors and outer jacket are insulated with TFE Tape.
Polymide Tape (Kapton) 
  • Suggested operating range: -400°F to 600°F (-240°C to 315°C)
  • Kapton is extremely tough.  It has excellent abrasion, impact and cut through resistance, very high resistance to oxidative degradation, weathering, and all chemicals except strong bases.  Kapton also offers high dielectric strength and insulation resistance.  Kapton does not support combustion; even at extremely high temperatures, it decomposes slowly without visible burning.  It is also resistant to radiation. The individual conductors and outer jacket are insulated with Kapton Tape.
Fiberglass 
  • Suggested maximum operating temperature: 900°F (482°C) continuous 1000°F (538°C) single exposure {Impregnation maintained to 400°F (200°C)}
  • Fiberglass insulation, with the special binder impregnation, offers good moisture and chemical resistance, as well as good abrasion resistance.  Typical applications include aerospace, foundries, heat treating, plastics industry and a wide variety of other uses.
  • Hi-Temp Fiberglass - Suggested maximum operating temperature: 1300°F (704°C) continuous, 1600°F (871°C) single exposure {Impregnation maintained to 400°F (200°C)}
For more information about thermocouple wire insulation materials contact Duro-Sense Corporation by calling 310-533-6877 or visiting https://duro-sense.com.

Friday, February 15, 2019

Temperature Sensing IS Rocket Science


Duro-Sense Corporation provides the precision temperature sensors to the aerospace, aviation, and space industries. Duro-Sense engineers bring proven solutions to your most difficult problems. Their R&D department is staffed with some of the industry's most qualified people, working in the most modern facilities to help advance the state of the art in temperature measurement.

Thursday, January 31, 2019

Thermocouples

thermocouple circuit
Diagram of a thermocouple circuit.
A thermocouple is a temperature measurement sensor. Thermocouples are made of two different metal wires, joined to form a junction at one end. The connection is placed on the surface or in the measured environment. As the temperature changes, the two different metals start to deform and cause resistance changes. A thermocouple naturally outputs a millivolt signal, so that the change in voltage can be measured as the resistance changes. Thermocouples are desirable because they are extremely low cost, easy to use and can provide precise measurements.

thermocouple
Typical sheathed thermocouple.
Thermocouples are produced in a variety of styles, such as sheathed, washer type, bayonet,  mineral insulated, hollow tube, food piercing, bare wire thermocouples or even thermocouple made from thermocouple wire only.

Because of their wide range of models and technical specifications, it is extremely important to understand their basic structure, functionality and range in order to better determine the right thermocouple type and material for an application.

Operating Principle

When two wires consisting of different metals are connected at both ends and one end is heated, a continuous current flows through the thermoelectric circuit. If this circuit is broken in the center, the net open circuit voltage (Seebeck Effect) depends on the temperature of the junction and the composition of the two metals. This means that a voltage is produced when the connection of the two metals is heated or cooled that can be correlated to the temperature.

Contact Duro-Sense Corporation with any questions about applying industrial and commercial thermocouples.

Duro-Sense Corporation
https://duro-sense.com
310-533-6877